본문 바로가기 주메뉴 바로가기
닫기

Business Info

Businesses

Formulation Business (R&D Center)

MS Therapeutics

As our own pharmaceutical Research Institute, we not only supply raw materials for pharmaceuticals, but also make it possible to produce and supply finished pharmaceuticals by transferring technology to pharmaceutical companies with weak R&D. In addition, we are developing innovative formulations with a pipeline of improved new drugs such as combination drugs or dossier form changes, rather than simple generics.

MS Therapeutics R&D Laboratory

Address
(16521) Room 1117(11F), 253, Samsung-ro,
Yeongtong-gu, Suwon-si, Gyeonggi-do, South Korea
Area
658/329m 2

History

Analytical Equipment

  • Analytical Balance

    METTLER
    Readability 0.1mg / Max 220g

  • pH Meter

    METTLER
    pH Accuracy ±0.002
    Temp Accuracy ±0.1 ℃

  • Karl Fisher

    METTLER
    Measurement Range 100ppm

  • Stability Chamber

    CARON
    Long Term(25℃, 60%RH) /
    Accelerated life(40℃, 75%RH)

  • UV-Vis Spectrophotometer

    Shimadzu
    Measurement Wavelength
    Range 185~ 900nm

  • HPLC

    Shimadzu
    Detector : VWD, PDA

  • Dissolution tester

    ERWEKA
    8 test stations
    Automatic sampling

  • Ultra Pure Water System

    Mirae ST
    Conductivity 1-25
    Resistivity 18.2 MΩ-cm
    TOC(ppb) <5

Pharmaceutical Equipment

  • High Share Mixer

    RAON XENA
    Impeller 500rpm
    Chopper : 4000rpm
    Container (2L, 4L)

  • FBGC

    Top & Bottom Spray System
    Working Capacity : 1 Kg

  • Rotary Tablet Press

    RAON XENA
    Station 8 / Main Comp 60KN
    Max Ejection press 5KN
    Turret Speed ~40rpm
    Diameter 25mm / Thickness 8mm
    Filling Depth 18mm

  • Tablet Coater

    RAON XENA
    Drum Speed ~40rpm
    Temp Cont. 30 ~ 85 ℃
    Drum (1L, 2L)

  • Conical Mill


    Hanningfield
    M05-U
    speed (650-6500 RPM)
    Low Particle Size : 150micon(80mesh)
    Screen : Round, Square type

  • Disintegration tester

    ERWEKA
    2 test racks
    30 ± 1 strokes/min
    accuracy ±0.2 °C

  • Hardness Tester

    ERWEKA
    measuring range: 3 - 500N
    Diameter Measurement : up to 28.00 mm
    Thickness Measurement : up to 12.00 mm

  • Friability Tester

    ERWEKA
    speed (20-100 RPM)

  • Viscometer

    Brookfield (Dvnext LV)
    1cP ~ 6M cP / 250 rpm

  • Overhead stirrer

    IKA (EUROSTAR 40 Digital)
    0/30 ~ 2000 rpm / 30,000 mPas

  • Homogenizer

    IKA
    (T50 digital ULTRA-TURRAX)
    600 ~ 10000 rpm
    5000 mPas

R&D Target Dosage Form

  • Solid

    Tablets, capsules (hard capsules,
    soft capsules), powders, granules, etc.

  • Semisolid

    Cream, gel, ointment

  • Liquid & Injection

    Liquids, Syrups, Suspensions &
    Injections, etc.

TOP